Voltage Plateform | 108V | 144V | 312V | 540V | |
Output | Output Voltage Range | 65V~132V | 100V~200V | 200V~450V | 400V~700V |
Output Current Range | 0~60A | 0~40A | 0~18A | 0~12A | |
Charge Model | Response Model(Control by CANBUS) | ||||
Charge Power | 6.6kW | ||||
Voltage Regulation Accuracy | ≤1% | ||||
Voltage Ripple coefficient | ≤1% | ||||
Current regulation accuracy | ≤5% | ||||
Output response time | ≤5S | ||||
Typical efficiency | ≥93% | ||||
Input | Input Voltage | 220VAC | |||
Input Voltage Range | 90~265VAC | ||||
Frequency Range | 50Hz(45~65Hz) | ||||
Inrush Current | ≤32A | ||||
Input Power Factor | ≥0.99(@220Vin,Pomax) | ||||
Environment | Working temperature | -40~55ºC | |||
Storage temperature | -40~60ºC | ||||
Humidity | 5%~95% | ||||
Protection Level | IP67 | ||||
Cooling | Fan cooling | ||||
Communication | CANBUS | ||||
Protection | Over Voltage Protection | Input overvoltage shutdown is self-recoverable, and output overvoltage shutdown is self-recoverable. | |||
Under Voltage Protection | Input undervoltage shutdown is self-recoverable, output undervoltage shutdown is self-recoverable. | ||||
Short Circuit Protection | Output short circuit shutdown, with self-recovery capability | ||||
Over Temperature Protection | When the temperature of the heat sink exceeds 75ºC, reduce the output power. When the temperature exceeds 95ºC, disconnect the circuit. Once the charging temperature returns to below 85ºC, the charger resumes outputting. | ||||
Reverse connection Protection | Output disconnected power supply does not start, gives an alarm, and returns to normal operation after restoration. | ||||
Power-off pretection | Abnormal condition - Cut off power supply |